REPOLEN FASER CLIMA PIPE

MCF (MULTICAPA CON FV, FASER)
Especially suitable for air conditioning installations due to its high heat tolerance.
Linear expansion five times lower than in single-layer tubes (0.03 vs. 0.15).
Complete safety in saline areas, exceptional resistance to corrosion, pressure, and great structural rigidity.
With acoustic and electrical insulation features. Recyclable material, lightweight, and easy to assemble.
Prevents blockages by removing scale, which also reduces pressure loss.
REPOLEN FASER CLIMA pipes, made of PPR-CT and fiberglass, offer great thermal and mechanical resistance, making them ideal for air conditioning and heating systems. Their fiber layer improves rigidity and reduces expansion, optimizing installation. They are suitable for industrial applications and comply with quality regulations. They are recyclable and not suitable for prolonged exposure to sunlight.

Structure

MCF (MULTICAPA CON FV, FASER)

Materials

PP-RCT / PP-RCT + FV / PP-RCT

Colour

BLUE WITH GREEN LINES

REGULATIONS

UNE EN 15874: Sistema de canalización en materiales plásticos para instalaciones de agua caliente y fría. Polipropileno (PP)
DIN 8077: Tuberías de polipropileno. Dimensiones
DIN 8078: Tuberías de polipropileno. Requerimientos generales de calidad y prueba
RP 001.78: Reglamento particular del Certificado de Conformidad AENOR para sistemas de canalización en Polipropileno Random con estructura PP-RCT y FV
UNE EN ISO 21003: Sistemas de canalización multicapa para instalaciones de agua caliente y fría en el interior de edificios.
CTE: Código Técnico de la Edificación
RD 03/2023: Establece criterios sanitarios de la calidad del agua de consumo humano

Material

Densidad 905 kg/m3
MFI (230º.2.16Kg) 0.30 g/10min
Resistencia a la tracción 25 Mpa
Alargamiento por tracción 10%
Módulo de elasticidad 900 Mpa
Coeficiente de conductividad térmica (λ) 0.15 w/m·k
Resistencia al impacto (Método de Charpy) (0ºC) 4 kJ/m2
Coeficiente lineal de expansión térmica (0º a 70º) 1.5 10-4 K-1

Product

Estructura MULTICAPA PP-RCT / PP-RCT + FV / PP-RCT
Color Interior verde RAL 6024 exterior azul RAL 5010 con 4 franjas verdes
Contenido en fibra de vidrio 18% capa FV. 6% total
Resistencia al impacto (Método de la escalera) Sin rotura <0.5m
Retracción longitudinal ≤1%
Opacidad Si
Rugosidad (k) 0.007 mm
Coeficiente de dilatación térmica lineal (α) 0.035 mm/mºC
Clasificación ante el fuego. Libre de halógenos B2
Resistencia a la presión interna
20ºC 1h 15MPa
Sin roturas
95ºC 22h 4.2MPa
Sin roturas
95ºC 165h 4MPa
Sin roturas
95ºC 1000h 3.8MPa
Sin roturas
Estabilidad térmica mediante ensayo de presión
110ºC  8760h 2.6MPa
Sin roturas
SDRCODEd (mm)di (mm)e (mm)Capacity (L/Mts)pesoMts/PackagesPallet Packages
7.4 430100003 20 14.4 2.8 0.163 0.15 120 24
7.4 430100006 25 18 3.5 0.254 0.23 80 28
SDRCODEd (mm)di (mm)e (mm)Capacity (L/Mts)pesoMts/PackagesPallet Packages
11 430100005 32 26.2 2.9 0.539 0.265 60 23
11 430210004 40 32.6 3.7 0.835 0.415 40 23
11 430210009 50 40.8 4.6 1.307 0.64 20 28
11 430100010 63 51.4 5.8 2.075 1.015 12 30
11 430100011 75 61.4 6.8 2.961 1.385 12 23
11 430100012 90 73.6 8.2 4.254 2.045 8 20
11 430210013 110 90 10 6.362 3.025 4 27
11 430100014 125 102.2 11.4 8.203 3.895 4 20
11 430100016 160 130.8 14.6 13.437 6.425 4 12
11 430100017 200 163.6 18.2 21.021 10.217 5.8 9
11 430100018 250 204.6 22.7 32.878 15.92 5.8 7
11 430100019 315 257.8 28.6 52.198 25.225 5.8 4
11 430100020 355 290.6 32.2 66.325 31.8 5.8 3
11 430100021 400 327.4 36.3 84.188 40.618 5.8 3
SDRCODEd (mm)di (mm)e (mm)Capacity (L/Mts)pesoMts/PackagesPallet Packages
17 430200031 125 110.2 7.4 9.537 2.666 4 20
17 430200028 160 141 9.5 15.614 4.381 4 12
17 430200029 200 176.2 11.9 24.383 6.828 5.8 9
17 430200030 250 220.4 14.8 38.152 10.582 5.8 7
17 430200019 315 277.6 18.7 60.524 17.114 5.8 4
17 430200020 355 312.8 21.1 76.846 21.75 5.8 3
17 430200021 400 352.6 23.7 97.646 27.492 5.8 3
17 430200023 500 440.6 29.7 152.468 42.995 5.8 2

REPOLEN FASER CLIMA pipes are composed of multiple layers of different materials. We identify it by the blue color of its last layer and the green lines, these lines also serve to align the fittings using them as a guide. They are mainly made of PPR-CT, which helps to minimize the effects of expansion and contraction caused by temperature variations throughout their service life. They offer excellent mechanical and chemical resistance. PPR-CT provides greater stability and strength compared to conventional PPR, which reduces degradation and improves the durability of the installation.

REPOLEN FASER CLIMA pipes can withstand more than 30 years under continuous exposure to 4.3ppm of sodium hypochlorite at 60ºC. In addition, the fiberglass interlayer increases structural rigidity and improves the ability to withstand high pressures and temperatures. The improved tensile strength reduces pipe expansion, allowing fewer supports and clamps to be used during installation. Thus, fiberglass not only optimizes thermal performance, but also reduces space requirements and lowers material costs. The REPOLEN FASER CLIMA pipe is the perfect choice for both residential and industrial projects. Designed for air conditioning installations both with fan coils and underfloor heating (including high temperature boilers, underfloor heating, radiators…).

PROJECTS

The REPOLEN FASER CLIMA pipe is manufactured according to UNE EN ISO 21003 and UNE EN ISO 15874 standards, with an AENOR certificate of product conformity (No. 001/006498) according to technical specification RP.01.72. Pipes made of polypropylene have a high capacity to resist chemical agents, both acids and alkalis, in addition to being resistant to many industrial substances. However, PPR should not be exposed to sunlight, since prolonged exposure to ultraviolet rays can cause damage to the material, accelerating its deterioration. We offer multi-layer PPR pipes with UV protection, specially designed for outdoor applications, such as the REPOLEN FASER RP UV / FASER CLIMA UV PIPE.

All REPOLEN pipes are made from virgin materials, as current regulations prohibit the use of recycled materials for drinking water. As part of our environmental commitment, we opt for sustainable and fully recyclable resources. REPOLEN FASER CLIMA pipes are available in SDR 7.4, SDR 11, and SDR 17, in a wide variety of diameters, from 20 mm to 500 mm.