REPOLEN FIRE RP PIPE

MCF (MULTI-LAYER WITH FV, FASER)
High fire resistance with Bs1d0 classification. Minimizes the risk of fire spread by not producing flammable droplets or particles.
Improves safety and visibility during a fire, facilitating evacuation.
Halogen-free, non-toxic and recyclable material.
Excellent resistance to extreme temperatures, corrosion and pressure, with great structural rigidity.
Eliminates scale and blockages, considerably reducing pressure loss.
The REPOLEN FIRE RP system, composed of multi-layer PP-RCT and fiberglass pipes, is designed for firefighting networks. It withstands high temperatures, pressure, and chemical agents. It is halogen-free, with a B-s1.d0C fire reaction classification, recyclable, and certified.

Structure

MCF (MULTI-LAYER WITH FV, FASER)

Materials

PP-RCT + ADDITIVE / PP-RCT + FV + ADDITIVE / PP-RCT

Colour

INTERIOR GREEN RAL 6024 AND EXTERIOR RED RAL 3028

REGULATIONS

UNE EN 12845: Fixed firefighting systems - Automatic sprinkler systems - Design. installation and maintenance
UNE EN 23500: Water supplies systems for firefighting
UNE EN 671: Fixed firefighting systems - Hose systems
RIPCI: Fire Protection Facilities Regulation (R.D 513/2017)
RSCIEI: Regulations for fire safety in industrial establishments (R.D 2267/2004)
CTE: Buildings’ Statute Book (R.D 314/2006 y R.D 732/2019)
UNE EN 13823: Reaction to fire tests for building products
UNE EN 13501: Fire classification of construction products and building elements
RP 001.84: Specific Regulations of the AENOR Certificate of Conformity for piping systems in random polypropylene (PPR). random polypropylene with modified crystalline structure. random polypropylene and fiberglass (FG) and polypropylene with modified structure and fiberglass for fire-fighting installations.
FM 1635-2021: Plastic Pipe and Fittings for Automatic Sprinkler Systems
ANSI/NFPA 13D-2022: “Instalation of Sprinkler System in One-and Two-Family Dwellings and Manufactured Homes”

PP-RCT Material

Density 905 kg/m3
MFI (230º.2.16Kg) 0.30 g/10min
Modulus of elasticity 25 Mpa
Impact resistance Charpy method at 0ºC 10%
Tensile strenght 900 Mpa
Tensile elongation 0.15 w/mk
Thermal conductivity coeficient (ƛ) 4 kJ/m2
Linear thermal expansion coeficient (0ºC to 70ºC) 1.5 10-4 K-1

Product

Structure MULTILAYER PP-RCT + Additive / PP-RCT + GF + Additive / PP-RCT
Color Green RAL 6024 interior and red RAL 3028 exterior
Glass fiber content 18% capa FV. 6% total
Impact resistance (Staircase method) No failures <0.5m
Longitudinal shrinkage ≤1%
Opacity Yes
Roughness (k) 0.007 mm
Linear thermal expansion coefficient (ɑ) 0.035 mm/mºC
Fire clasification. Halogen free B-s1. d0
SDRCoded (mm)di (mm)e (mm)Capacity (L/Mts)Weight (kg/m)Mts/PackagesPallet Packages
7.4 431500006 25 20.4 3.5 0.254 0.26 80 28
SDRCoded (mm)di (mm)e (mm)Capacity (L/Mts)Weight (kg/m)Mts/PackagesPallet Packages
11 430500005 32 26.2 2.9 0.539 0.297 60 23
11 430500004 40 32.6 3.7 0.835 0.463 40 23
11 430500009 50 40.8 4.6 1.307 0.718 20 28
11 430500010 63 51.4 5.8 2.075 1.093 12 30
11 430500011 75 61.4 6.8 2.961 1.553 12 23
11 430500012 90 73.6 8.2 4.254 2.262 8 20
11 430500013 110 90 10 6.362 3.36 4 27
11 430500014 125 102.2 11.4 8.203 4.301 4 20
11 430500016 160 130.8 14.6 13.437 6.821 4 12
11 430500017 200 163.6 18.2 21.021 10.217 5.8 9

The REPOLEN FIRE RP System is composed of pipes and fittings designed for fire extinguishing installations through the application of automatic sprinklers and equipped fire hydrants (BIE). This firefighting system consists of multilayer pipes manufactured with an inner layer of random copolymer polypropylene copolymer with modified crystalline structure of the latest generation (PP-RCT). The intermediate layer of the ppr fire protection pipe is made of PP-RCT and additivated fiberglass, minimizing the possible effects of expansion and contraction due to temperature changes that the pipe could experience during its useful life. The external layer is composed of PP-RCT and a fireproof additive that protects it from fire.

This system of pipes and fittings is suitable for fire-fighting installations of wet pipes permanently charged with pressurized water. We have reaction to fire classification B-s1,d0, DIT certificates (technical suitability) for specific water supply networks of fire extinguishing installations for both automatic sprinklers and equipped fire hydrant networks (bie) and American certification FM1635 by ICC ES. The REPOLEN FIRE RP system is halogen-free, as its composition does not contain fluorine, chlorine, bromine, iodine and astatine. This means that it does not contain elements that during combustion release hazardous substances in the form of smoke that are toxic to people and cause corrosion of metals.

PROJECTS

REPOLEN FIRE RP pipes are manufactured following the requirements of the UNE EN ISO 15874 standard, adding an additive for adequate fire resistance for fire installations. Polypropylene pipes have outstanding resistance to chemical agents, resisting both acids and alkalis, as well as many substances used in the industry. However, PPR should not be exposed to the sun’s UV rays, as continuous exposure causes the material to degrade, accelerating its aging process.

Each of our REPOLEN pipes is manufactured with original material, as regulations do not authorize the use of recycled materials for drinking water. Thanks to our environmental responsibility, we use sustainable materials and the pipes are 100% recyclable. REPOLEN FIRE RP pipe is available in SDR 7.4 and SDR11, in a wide variety of diameters, from 25 mm to 160 mm.

FIRE Accessories